780 research outputs found

    Response to ranibizumab therapy in neovascular AMD - an evaluation of good and bad responders

    Full text link
    Background: Treatment of neovascular age-related macular degeneration (AMD) with Lucentis® shows a broad spectrum regarding the course of visual acuity (VA). While some patients show a good response (increase in VA), others disclose much less promising results. Patients and Methods: A retrospective data analysis of all eyes treated for neovascular AMD at the University Hospital of Zurich, Switzerland for at least 12 months was carried out. The courses of VA between the 90th (good responders, GR) and the 10th (bad responders, BR) percentiles were compared at 3, 12 and 24 months from baseline. An analysis regarding demographic data, lesion type and size as well as injection frequency and visits was done and predictive factors for GR and BR were evaluated. Results: Marked differences in the course of VA between GR (n = 30) and BR (n = 30) are already observed 3 months from baseline. In GR the gains in VA after 3, 12 and 24 were 15.7 ± 9 letters ETDRS, 25.3 ± 7 and 14.0 ± 14. BR showed a deterioration of 8.3 ± 11 letters ETDRS after 3, 22.1 ± 8 after 12 and 23.6 ± 13 after 24 months. The gender distribution was equal with a higher percentage of female patients (64 % in BR and 66 % in GR). The baseline VA was statistically significantly lower in GR (45.7 ± 10 vs. 55.4 ± 11, p < 0.05) than in BR. No other significant differences in baseline data were found, and no predictor for group membership could be identified. Conclusions: Only the course of VA in the first three months seems to be of value for an estimation of the response to treatment. In the future the response to treatment in the early phase may influence the treatment algorithm and the injection frequency

    Metal on metal hip resurfacing versus uncemented custom total hip replacement - early results

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>There is no current consensus on the most appropriate prosthesis for treating symptomatic osteoarthritis (OA) of the hip in young, active patients. Modern metal on metal hip resurfacing arthroplasty (HR) has gained popularity as it is theoretically more stable, bone conserving and easier to revise than total hip arthroplasty. Early results of metal on metal resurfacing have been encouraging. We have compared two well matched cohorts of patients with regard to function, pain relief and patient satisfaction.</p> <p>Methods</p> <p>This prospective study compares 2 cohorts of young, active patients treated with hip resurfacing (137 patients, 141 hips) and custom uncemented (CADCAM) stems (134 patients, 141 hips). All procedures were performed by a single surgeon. Outcome measures included Oxford, WOMAC and Harris hip scores as well as an activity score. Statistical analysis was performed using the unpaired student's t-test.</p> <p>Results</p> <p>One hundred and thirty four and 137 patients were included in the hip replacement and resurfacing groups respectively. The mean age of these patients was 54.6 years. The mean duration of follow up for the hip resurfacing group was 19.2 months compared to 13.4 months for the total hip replacement group.</p> <p>Pre operative oxford, Harris and WOMAC scores in the THA group were 41.1, 46.4 and 50.9 respectively while the post operative scores were 14.8, 95.8 and 5.0. In the HR group, pre- operative scores were 37.0, 54.1 and 45.9 respectively compared to 15.0, 96.8 and 6.1 post operatively. The degree of improvement was similar in both groups.</p> <p>Conclusion</p> <p>There was no significant clinical difference between the patients treated with hip resurfacing and total hip arthroplasty in the short term.</p

    Head-to-head comparison of the WHO STEPwise approach with immediate unattended and delayed unattended automated blood pressure measurements during household-based screening: a diagnostic accuracy study in Lesotho

    Get PDF
    BACKGROUND: WHO introduced the STEPwise approach to surveillance (STEPS) to monitor trends in non-communicable diseases. For arterial hypertension, the STEPS protocol takes the average of the last two out of three standard blood pressure measurements (SBPM). This study assesses the diagnostic accuracy of SBPM, same-day and next-day unattended automated measurement (uABP), with 24 h ambulatory measurement (24 h-ABPM) as reference. METHODS: This diagnostic accuracy study was done within a population-based household survey on cardiovascular risk factors in two districts in Northern Lesotho. Adults (aged ≥ 18 years) with elevated SBPM (defined as ≥140/90 mmHg), and 2:1 age- and sex-matched participants with normal SBPM during the survey were recruited. Following SBPM, first uABP readings were obtained on survey day. Afterwards, participants received a 24 h-ABPM device. Second uABP readings were taken 24 h later, after retrieval of the 24 h-ABPM. The main outcome was overall diagnostic accuracy of all screening measurements (SBPM, first uABP, and second uABP), determined using area under the receiver operating characteristic curve (AUROC), with 24 h-ABPM as a reference. FINDINGS: Between November 2, 2021 and August 31, 2022, 275 participants (mean age 58 years (SD: 16 years), 163 (59%) female) were enrolled, 183 of whom had elevated and 92 had normal SBPM. Mean difference between systolic daytime 24 h-ABPM and screening measurements was highest for SBPM (mean difference: -13 mmHg; 95% CI: -14 to -11). Mean difference between diastolic daytime 24 h-ABPM and diastolic SBPM was -2 mmHg (95% CI: -4 to -1), whereas no difference was found for mean diastolic first uABP (mean difference: -1 mmHg; 95% CI: -2.0 to 0.3); and mean diastolic second uABP (mean difference: 1.0 mmHg; 95% CI: -0.4 to 2.3). White coat hypertension was highest with SBPM (55 [20%]), followed by first uABP (27 [9.8%]), and second uABP (18 [6.5%]). Using systolic daytime 24 h-ABPM as a reference, the uABPs had higher AUROC (first uABP: 87% [95% CI: 83-91]; second uABP: 88% [95% CI: 84-92]); SBPM: (79% [95% CI: 74-85]). This difference was significant between first uABP and SBPM (P = 0.0024), and between second uABP and SBPM (P = 0.0017). INTERPRETATION: uABP had better diagnostic performance than SBPM. Integration of uABP into STEPS protocol should be considered. FUNDING: Swiss Agency for Development and Cooperation under the ComBaCaL project, and the World Diabetes Foundation

    Mathematical evaluation of jumping distance in total hip arthroplasty: Influence of abduction angle, femoral head offset, and head diameter

    Get PDF
    Background and purpose The jumping distance (JD) is the degree of lateral translation of the femoral head center required before dislocation occurs. The smaller the distance, the higher the theoretical risk of dislocation. The aim of our study was to evaluate this jumping distance and its variation according to the characteristics of the implant, and also the theoretical gain in using large head diameters of above 38 mm
    • …
    corecore